7. COMMUNICATION DATA LIST
IMR01Y06-E6
38
Continued from the previous page.
Address Communication item Data range
Factory
set value
RX(n+5)9 Device address 14 Event 1 state 0: OFF
1: ON
RX(n+5)A Event 2 state
RX(n+5)B Burnout state 0: OFF
1: ON
RX(n+5)C Heater break alarm
(HBA) state
0: OFF
1: ON
RX(n+5)D PID/AT transfer 0: PID control
1: Autotuning (AT)
RX(n+5)E Unused
RX(n+5)F
RX(n+6)0 Device address 15 Event 1 state 0: OFF
1: ON
RX(n+6)1 Event 2 state
RX(n+6)2 Burnout state 0: OFF
1: ON
RX(n+6)3 Heater break alarm
(HBA) state
0: OFF
1: ON
RX(n+6)4 PID/AT transfer 0: PID control
1: Autotuning (AT)
RX(n+6)5 Device address 16 Event 1 state 0: OFF
1: ON
RX(n+6)6 Event 2 state
RX(n+6)7 Burnout state 0: OFF
1: ON
RX(n+6)8 Heater break alarm
(HBA) state
0: OFF
1: ON
RX(n+6)9 PID/AT transfer 0: PID control
1: Autotuning (AT)
RX(n+6)A Unused
y
y
y
RX(n+6)F
RX(n+7)0 Device address 17 Event 1 state 0: OFF
1: ON
RX(n+7)1 Event 2 state
RX(n+7)2 Burnout state 0: OFF
1: ON
RX(n+7)3 Heater break alarm
(HBA) state
0: OFF
1: ON
RX(n+7)4 PID/AT transfer 0: PID control
1: Autotuning (AT)