RKC INSTRUMENT COM-JC Manuel d'instructions Page 41

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 106
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 40
7. COMMUNICATION DATA LIST
IMR01Y06-E6
35
7.1.3 4 stations occupied 2 times
Remote input
Data direction: COM-JC (Remote device station) Master station (PLC)
Data capacity: 224-bit
Address Communication item Data range
Factory
set value
RXn0 Device address 1
Event 1 state
0: OFF
1: ON
RXn1
Event 2 state
RXn2
Burnout state
0: OFF
1: ON
RXn3
Heater break alarm
(HBA) state
0: OFF
1: ON
RXn4
PID/AT transfer
0: PID control
1: Autotuning (AT)
RXn5 Device address 2
Event 1 state
0: OFF
1: ON
RXn6
Event 2 state
RXn7
Burnout state
0: OFF
1: ON
RXn8
Heater break alarm
(HBA) state
0: OFF
1: ON
RXn9
PID/AT transfer
0: PID control
1: Autotuning (AT)
RXnA Unused
RXnB
RXnC Extended display completion 0: OFF
1: ON
RXnD Extended setting completion 0: OFF
1: ON
RXnE Unused
RXnF Hardware error flag
0: OFF
1: ON
Hardware error flag ON condition
Hardware error
RAM read/write error
Stack overflow
Memory backup error
Configuration error
RX(n+1)0 Unused
y
y
y
RX(n+1)F
RX(n+2)0 Device address 3
Event 1 state
0: OFF
1: ON
RX(n+2)1
Event 2 state
RX(n+2)2
Burnout state
0: OFF
1: ON
RX(n+2)3
Heater break alarm
(HBA) state
0: OFF
1: ON
RX(n+2)4
PID/AT transfer
0: PID control
1: Autotuning (AT)
Continued on the next page.