4. WIRING
IMR01Y06-E6
10
4.3 Connection to PLC
Connection method
The PLC (Master station) and COM-JC make multi-drop connection in CC-Link dedicated cable Ver. 1.10.
CC-Link dedicated cable
Ver. 1.10
Up to 61 stations
PLC
Master station
Termination
resistor
Station to station
cable length:
20 cm or more
COM-JC
Termination
resistor
Up to 64 stations:
1 station occupied 1 time
z
Communication speed and maximum transmitter distance
(Use the CC-Link dedicated cable Ver. 1.10)
Communication
speed
Station to station
cable length
Maximum transmitter distance
(maximum length of network)
10 Mbps
20 cm or more
100 m
5 Mbps 160 m
2.5 Mbps 400 m
625 kbps 900 m